FL – FRNC
Baja elevación - altura de recorrido máximo 80m
Drawing according to article number 182205; Type 8827-F
Variantes de productos y existencias
Descargar
| Artículo No. | Stock | Prodotto | Diseño de cables | Prop. CU [kg/km] | Peso [kg/km] | GTIN / EAN |
|---|---|---|---|---|---|---|
| 191111 | 8636-F | 12 G 0.75 + 3 x 2 x 0.50 mm² (FTP) | 123 | 420 | 40393910069709 | |
| 182205 | 8827-F | 3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.34 mm² (FTP) | 244 | 735 | 40393910077766 | |
| 191113 | 8582-F | 24 G 1.00 + 3 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 306 | 958 | 40393910069686 | |
| 190491 | 8582-F | 2 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 1 CX 75 Ω | 149 | 524 | 40393910070873 |
Especificaciones técnicas
Cable de suspensión de ascensores de interior y panorámicos.
| Pair/quad | various colours or black with white numbers |
|---|---|
| Core | black, white numbered, G = with green-yellow core(s) |
| Coax | negro |
| Temperatura de funcionamiento | -15 °C - +70 °C |
| Rated voltage Uo/U | de acuerdo con la tabla |
|---|
| Aplicaciones | Para cumplir con los procedimientos de instalación correctos, por favor, consulte el manual de instalación de Datwyler que está disponible por separado. |
|---|
| Core insulation | bajo riesgo de incendio |
|---|---|
| Core flexible | clase 5 |
| Supporting members | ninguno |
| Material exterior de la vaina | low fire hazard |
| Color de la funda exterior | negro |
| Estándar para cables flexibles de control de ascensores | EN 50214 |
|---|
| Maximum travelling height | 80 m |
|---|---|
| Maximum free suspension | 45 m |
| Maximum running speed | 4 m/s |
| Recommended loop diameter | de acuerdo con la tabla, tolerancia -50/+100 mm |
| Acceleration | 0.8 m/s² |