FO Indoor Duplex / I-V(ZN)HH

2.0 mm, LS0H, Euroclass Fca
Semi-tight buffer
flame retardant - IEC 60332.1

1 Fibre
2 Semi-tight buffer
3 Aramid yarn
4 Single-fibre cable: 2.0 mm
5 LS0H sheath

04_Propagation 05_Spread- 06_Density 08_System- 03_LS0H CPR_Fca

Product variants & stock

Article No. Stock ProductReaction to fireOuter sheath colourFibre typeFibre categoryOuter sheath materialOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Fire load [kWh/m]Packing unitGTIN / EAN
19209000FZ
FO Indoor DuplexFcagreenE9/125 G.652.D OS2OS2FRNC/LSZH4.85015.120030000.1by the metre40393910027921
19209100FZ
FO Indoor DuplexFcayellowE9/125 G.652.D OS2OS2FRNC/LSZH4.85015.220030000.1by the metre40393910027914
19209300FZ
FO Indoor DuplexFcaturquoiseG50/125 OM3OM3FRNC/LSZH4.85015.120030000.1by the metre40393910027891
19293300FZ
FO Indoor DuplexFcaheather violetG50/125 OM4OM4FRNC/LSZH4.85015.220030000.1by the metre40393910026658

Technical specifications

Robust and flexible fibre optic Duplex cable, based on 2 single-fibre cables 2.0 mm
with semi tight buffer 0.9 mm in a common sheath.
Easy handling, easy to strip off.
Flame retardant halogen-free LS0H sheath.
Low fire load.
Maximum number of fibres 2
Installation temperature -10 °C - +50 °C
Operating temperature -20 °C - +60 °C
Imprint DATWYLER FO Indoor Duplex / I-V(ZN)HH «No. of fibres» «Fibre type» «Batch no.» «CPR Class» MADE IN SWITZERLAND «Receiver wave receiver wave» «Meter marks»
Field of application Indoor
Suitable for patch cables between terminal distributors and/or end devices.
For direct termination with connectors.
Can also be spliced in terminal distributors.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Reaction to fire EN 13501-6
Euroclass Fca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, SEV TP 20B/3C 3.4.1.1
Outer sheath material FRNC/LSZH

Documentation